A - 101
Appendices
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User’s Manual (I586)
A-4 Sysmac Error Status Codes
A
A-4-1 Error List
08390000 Power Module Error An error was detected in the
power module.
There is a short-circuit,
ground fault, or contact fail-
ure on the U, V, or W motor
cable
There is a short-circuit on
the wiring of External
Regeneration Resistor or
the resistance value is small
The insulation resistance
failed between the U, V, or
W motor cable and the
motor ground wire
Servo Drive failure
P. A-118
083B0000 Self-diagnosis Error An error was detected by
the self-diagnosis of the
safety function.
False detection due to a
data read error that was
caused by excessive noise
Hardware failure
P. A-119
083C0000 Main Circuit Tem-
perature Monitoring
Circuit Failure
A temperature monitoring
circuit failure was detected
on the main circuit.
Broken wiring of the therm-
istor, temperature monitor-
ing circuit failure
P. A-119
083D0000 Fan Error The rotation speed of the
fan is 40% or less of the rat-
ing and the cooling perfor-
mance decreases.
There is a foreign matter in
the cooling fan and it blocks
the rotation
Cooling fan failure
P. A-12 0
083F0000 Regeneration Pro-
cessing Error
The regeneration process-
ing was stopped to protect
the Regeneration Resistor.
The regeneration process-
ing is set inappropriately
The Regeneration Resistor
is selected inappropriately
The Regeneration Resistor
is used for continuous
regenerative braking
The applied power supply
voltage is higher than the
specified value
Regeneration Resistor fail-
ure
P. A-12 1
08410000 Overvoltage Error The main circuit power sup-
ply voltage (P-N voltage)
exceeded the operation
guarantee range.
The P-N voltage exceeded
the specified value
The input voltage increased
The Regeneration Resistor
wiring is broken
The External Regeneration
Resistor is set or selected
inappropriately
Servo Drive failure
P. A-12 2
08420000 Motor Overheat
Error
The encoder detected the
temperature that exceeded
the protection level of motor.
The temperature is high
around the motor
The motor is overloaded
Encoder failure
P. A-12 3
Event code
(hex)
Event name Description Assumed cause
Level
Refer-
ence
Min
Obs
Info