12-9
12-3 Errors
OMNUC G5-series AC Servomotors and Servo Drives User’s Manual (with Built-in EtherCAT Communications)
12
Troubleshooting and Maintenance
34 0
Overrun Limit Error
√√
36 0 to 2
Object Error
−−
37 0 to 2
Object Corrupted
−−
38
0 Drive Prohibition Input Error 1 −√
1 Drive Prohibition Input Error 2 −√
40 0
Absolute Encoder System Down
Error
√√
*3
41 0
Absolute Encoder Counter
Overflow Error
√−
42 0
Absolute Encoder Overspeed
Error
√√
*3
43 0
Encoder Initialization Error
√−
44 0
Absolute Encoder 1-rotation
Counter Error
√−
45 0
Absolute Encoder Multi-rotation
Counter Error
√−
47 0
Absolute Encoder Status Error
√−
48 0 Encoder Phase-Z Error √−
49 0 Encoder CS Signal Error √−
50
0 External Encoder Connection Error √−
1
External Encoder Communications Data
Error
√−
51
0 External Encoder Status Error 0 √−
1 External Encoder Status Error 1 √−
2 External Encoder Status Error 2 √−
3 External Encoder Status Error 3 √−
4 External Encoder Status Error 4 √−
5 External Encoder Status Error 5 √−
55
0 Phase-A Connection Error √−
1 Phase-B Connection Error √−
2 Phase-Z Connection Error √−
83
1 EtherCAT State Change Error √√
2 EtherCAT Illegal State Change Error √√
3 Communications Synchronization Error √√
4 Synchronization Error √√
5 Sync Manager WDT Error √√
87 0 Immediate Stop Input Error −√
Error No. (hex)
Error detection function
Attribute
Main Sub History
Can be
reset
Immediate
stop
*1
ABS
ABS
ABS
ABS
ABS
ABS

Table of Contents