9 - 23
9 Servo Parameter Objects
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
9-3 Vibration Suppression Settings
9
Set damping frequency 3 to suppress vibration at the end of the load in damping control.
Measure the frequency of vibration at the end of the load and make the setting in units of 0.1 Hz.
The range of setting frequency is 1.0 to 200.0 Hz. The function is disabled if the setting is 0 to 0.9 Hz.
For details, refer to 11-5 Damping Control on page 11-17.
First set Damping Frequency 3 (3218 hex). Then reduce the setting if force saturation occurs or
increase the setting to increase operation speed. Normally, use a setting of 0.
The upper limit of the set value is restricted to the corresponding damping frequency or the value of
(2,000 - damping frequency), whichever is the smaller.
For details, refer to 11-5 Damping Control on page 11-17.
Set damping frequency 4 to suppress vibration at the end of the load in damping control.
Measure the frequency of vibration at the end of the load and make the setting in units of 0.1 Hz.
The range of setting frequency is 1.0 to 200.0 Hz. The function is disabled if the setting is 0 to 0.9 Hz.
For details, refer to 11-5 Damping Control on page 11-17.
First set Damping Frequency 4 (3220 hex). Then reduce the setting if force saturation occurs or
increase the setting to increase operation speed. Normally, use a setting of 0.
The upper limit of the set value is restricted to the corresponding damping frequency or the value of
(2,000 - damping frequency), whichever is the smaller.
For details, refer to 11-5 Damping Control on page 11-17.
3218 hex
Damping Frequency 3
Setting
range
0 to 2,000
Unit
0.1 Hz
Default
setting
0 Data
attribute
B
Size 2 bytes (INT16) Access RW PDO map Not possible
3219 hex
Damping Filter 3 Setting
Setting
range
0 to 1,000
Unit
0.1 Hz
Default
setting
0 Data
attribute
B
Size 2 bytes (INT16) Access RW PDO map Not possible
3220 hex
Damping Frequency 4
Setting
range
0 to 2,000
Unit
0.1 Hz
Default
setting
0 Data
attribute
B
Size 2 bytes (INT16) Access RW PDO map Not possible
3221 hex
Damping Filter 4 Setting
Setting
range
0 to 1,000
Unit
0.1 Hz
Default
setting
0 Data
attribute
B
Size 2 bytes (INT16) Access RW PDO map Not possible
csp
pp
hm
csp
pp
hm
csp
pp
hm
csp
pp
hm