6
Observe the following precautions when wiring connector for power supply/regenerative
unit.
• Remove the connector for power supply/regenerative unit from the SERVOPACK prior to
wiring.
• Insert only one wire per terminal on the connector for power supply/regenerative unit.
• Make sure that the core wire is not electrically shorted to adjacent core wires.
Be sure to wire correctly and securely.
Failure to observe this caution may result in motor overrun, injury, or malfunction.
Always use the specified power supply voltage of single-phase 200 V to 230 V without
connecting directly to a voltage of 400 V.
The SERVOPACK will be destroyed.
Take appropriate measures to ensure that the input power supply is supplied within the
specified voltage fluctuation range. Be particularly careful in places where the power sup-
ply is unstable.
An incorrect power supply may result in damage to the product.
Install external breakers or other safety devices against short-circuiting in external wiring.
Failure to observe this caution may result in fire.
Take appropriate and sufficient countermeasures for each when installing systems in the
following locations.
Failure to observe this caution may result in damage to the product.
• Locations subject to static electricity or other forms of noise.
• Locations subject to strong electromagnetic fields and magnetic fields.
• Locations subject to possible exposure to radioactivity.
• Locations close to power supplies including power supply lines.
Do not reverse the polarity of the battery when wiring with regenerative unit.
Failure to observe this caution may result in damage to the product.