Appendices
A-96
CP2E CPU Unit Software User’s Manual(W614)
A723
to
A725
Power ON Clock Data
2
These words contain the time at which
the power was turned ON two times
before the startup time stored in words
A510 to A511.
A723.00 to A723.07: Seconds (00 to
59)
A723.08 to A723.15: Minutes (00 to
59)
A724.00 to A724.07: Hour (00 to 23)
A724.08 to A724.15: Day of month (01
to 31)
A725.00 to A725.07: Month (01 to 12)
A725.08 to A725.15: Year (00 to 99)
See at left. Retained Retained Written when
power is
turned ON.
A726
to
A728
Power ON Clock Data
3
These words contain the time at which
the power was turned ON three times
before the startup time stored in words
A510 to A511.
A726.00 to A726.07: Seconds (00 to
59)
A726.08 to A726.15: Minutes (00 to
59)
A727.00 to A727.07: Hour (00 to 23)
A727.08 to A727.15: Day of month (01
to 31)
A728.00 to A728.07: Month (01 to 12)
A728.08 to A728.15: Year (00 to 99)
See at left. Retained Retained Written when
power is
turned ON.
A729
to
A731
Power ON Clock Data
4
These words contain the time at which
the power was turned ON four times
before the startup time stored in words
A510 to A511.
A729.00 to A729.07: Seconds (00 to
59)
A729.08 to A729.15: Minutes (00 to
59)
A730.00 to A730.07: Hour (00 to 23)
A730.08 to A730.15: Day of month (01
to 31)
A731.00 to A731.07: Month (01 to 12)
A731.08 to A731.15: Year (00 to 99)
See at left. Retained Retained Written when
power is
turned ON.
A732
to
A734
Power ON Clock Data
5
These words contain the time at which
the power was turned ON five times
before the startup time stored in words
A510 to A511.
A732.00 to A732.07: Seconds (00 to
59)
A732.08 to A732.15: Minutes (00 to
59)
A733.00 to A733.07: Hour (00 to 23)
A733.08 to A733.15: Day of month (01
to 31)
A734.00 to A734.07: Month (01 to 12)
A734.08 to A734.15: Year (00 to 99)
See at left. Retained Retained Written when
power is
turned ON.
A735
to
A737
Power ON Clock Data
6
These words contain the time at which
the power was turned ON six times
bef
o
re the startup time stored in words
A510 to A511.
A735.00 to A735.07: Seconds (00 to
59)
A735.08 to A735.15: Minutes (00 to
59)
A736.00 to A736.07: Hour (00 to 23)
A736.08 to A736.15: Day of month (01
to 31)
A737.00 to A737.07: Month (01 to 12)
A737.08 to A737.15: Year (00 to 99)
See at left. Retained Retained Written when
power is
turned ON.
Address
Name Function Settings
Status
after
mode
change
Status at
startup
Write
timing
Related
flags,
settings
Words Bits

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC CP2E-N D Series and is the answer not in the manual?

Omron SYSMAC CP2E-N D Series Specifications

General IconGeneral
BrandOmron
ModelSYSMAC CP2E-N D Series
CategoryComputer Hardware
LanguageEnglish

Related product manuals