107
RFID System
User's Manual
Section 4 Data Carrier
Section 4
Functions
Using the OVERWRITE COUNT Command
Example: When the three bytes from address 0010H are used as the overwrite count area.
1. The overwrite count initial value of
100,000 times is written in the control
area.
“WTH10010
2. Enter the overwrite count of 5.
“MDS1001005”
A total of 5 times will be decremented from
100,000.
3. The accumulated count is 100,000 times.
When “MDS1001000” is executed, it will be “MD76” (overwrite count exceeded.)
0010
0011
0012
86H
01H
A0H
0010
0011
0012
86H
9BH
01H
0010
0011
0012
00H
00H
00H