Section 3 Communications Subcommands
RFID System
User's Manual
Section 3
Commands
Communications Subcommands
Communications subcommands are used together with communications commands. Communications with
the Data Carrier cannot be performed using only these subcommands.
COMMAND PROCESSING TERMINATE (AA)
Terminates the processing of the communications commands and error noise detection commands,
and restores the command wait status.
End code Indicates the execution result for the command.
00: Normal completion
15: Command processing not executed.
For details on end codes, refer to End code List.
p.95
Termination timing Indicates the timing for terminating command processing.
0: Terminated before Data Carrier detection.
1: Terminated during Data Carrier detection.
Command
AA
2
2
CR
Command
code
Terminator
Response
Command
code
AA
00
22
2
CR
Terminator
End code
×
1
Termination
timing