RFID System
User's Manual
Section 6 Specifications and Dimensions
Section 6
Appendices
119
Transmission Specifications
Transmission with the currently available V600-series Data Carriers is possible.
•Transmission Distances
Note 1: Data Carrier Installation Conditions
Note 2: When using the V600-D23P66N at temperatures of
10°C or lower, transmission may not be
possible at the specified distance. In this case, move the Reader Writer slightly further away
from the Data Carrier.
Data Carrier Transmission distance
V600-D23P53 0 to 2.5 mm
V600-D23P54 0 to 4 mm
V600-D23P55 0 to 10 mm
V600-D23P61 0 to 11 mm
V600-D23P66N 0 to 17 mm (See note 2.)
V600-D23P66SP 0 to 12 mm
V600-D23P71 0 to 25 mm
V600-D23P72 0 to 23 mm
V600-D8KR04 0 to 35 mm
V600-D8KR12 0 to 25 mm
V600-D8KR13 0 to 20 mm
V600-D2KR16 0 to 10 mm
V600-D8KF04 0 to 18 mm
V600-D23P53/P54 Embedded in metal (iron).
V600-D23P55 Embedded in resin
V600-D23P61 Metal (iron) on the back surface of the Data Carrier.
V600-D23P66N/P66SP/P71/P72 Resin on the back surface of the Data Carrier. Data Carrier (no metal on back
surface)
V600-D8KR04/R12/R13/D8KF04 Metal (iron) on the back surface of the Data Carrier.
V600-D2KR16 Data Carrier installed on a bracket and attached to a metal (aluminium) plate.
25.4±1
54±1
48±1
9.5±0.3
4+0.1 dia.
V600-A22
(Unit: mm)

Related product manuals