RFID System
User's Manual
Section 3
l
Communications with the Data Carrier
Section 3
Commands
Button Auto Commands
Button auto commands execute auto commands after a command is sent from the host device and the activate
switch of the Hand-held Reader Writer is pressed.
1. A command is sent from the host device to the Hand-held Reader Writer.
2. Press the Hand-held Reader Writer activate switch.
3. The Hand-held Reader Writer enters the communication stand-by state with the Data Carrier, and the
operation indicator (LED) flashes green.
If the Data Carrier is not detected within one minute of sending the command, a timeout will occur and a Data Carrier
Non-existent Error will occur. As a result, the operation indicator will flash red.
4. Communications with the Data Carrier are performed when the antenna end of the Hand-held Reader
Writer is moved near the Data Carrier.
5. A response is returned from the Hand-held Reader Writer to the host device.
If communications end normally, the operation indicator (LED) lights green and then turns OFF.