57
RFID System
User's Manual
Section 3
l
Communications Commands
Section 3
Commands
Processing Area Number: 1
Processing Area Number: 2
End code Indicates the execution result for the command.
The end code 00 indicates normal completion.
For details on end codes, refer to End code List.
p.95
Read data Indicates the data read from the Data Carrier.
The characters in ASCII indicate the number of read bytes and the characters in hexadecimal code
indicate the number of read bytes x 2.
Response
×
Command
code
BR
×
00
××
22 n
2
CR
Terminator
Read data
End code
××
Command
code
BR
×
00
××
22 n
2
CR
Terminator
Read data
area (1)
×
Read data
area (2)
××
n
End code
Area