EasyManua.ls Logo

Omron V600 - Page 74

Omron V600
138 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
72
Section 3 Communications Commands
RFID System
User's Manual
Section 3
Commands
EXPANSION DIVIDED AUTO WRITE (NW)
This command divides and writes up to 2 Kbytes of data to the Data Carrier when the Hand-held
Reader Writer is moved close to the Data Carrier. The Hand-held Reader Writer responds when com-
munications between the Hand-held Reader Writer and Data Carrier have ended. The host device can-
not send commands to the Hand-held Reader Writer until all the responses have been received
Frame 1
Frames 2 to n
Data setting Specifies the code format used to send write data to the Data Carrier.
A: ASCII
H: Hexadecimal code
Processing area number
setting
Always 1.
Write area start address Specifies the start address of the area to be written to in 4-digit hexadecimal.
Setting range: 0000h to 1FFFh
Write data Indicates the data to be written to the Data Carrier.
Data can be between 0 and 257 characters.
Terminator Indicates the end of the frame.
CR: Succeeding frame
*CR: No succeeding frame
Write data Indicates the data to be written to the Data Carrier.
Data can be between 0 and 265 characters.
Terminator Indicates the end of the frame.
CR: Succeeding frame
*CR: No succeeding frame
End code Indicates the execution result for the command.
The end code 00 indicates normal completion.
For details on end codes, refer to End code List.
p.95
Command
××
NW
××
A/H 1
××
211 4
2
CR
n
××
Command
code
Data
setting
Processing
area
number
setting
Write area
start address
Write data
Terminator
××
××××
1 or 2
CR
n
××
Terminator
Write data
Response
Command
code
NW
00
22
2
CR
Terminator
End code