EasyManua.ls Logo

Omron V600 - Page 79

Omron V600
138 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
77
RFID System
User's Manual
Section 3
l
Communications Commands
Section 3
Commands
EXPANSION BATCH AUTO WRITE (aw)
This command writes up to 2 Kbytes of data to the Data Carrier in a batch when the Hand-held Reader
Writer moves close to the Data Carrier. The Hand-held Reader Writer responds when communications
between the Hand-held Reader Writer and Data Carrier have ended.
Data setting Specifies the code format used to send write data to the Data Carrier.
A: ASCII
H: Hexadecimal code
Processing area number
setting
Always 1.
Write area start address Specifies the start address of the area to be written to in 4-digit hexadecimal.
Setting range: 0000h to 1FFFh
Write data Indicates the data to be written to the Data Carrier.
The maximum number of bytes that can be written at one time is 2,048 bytes.
Setting range: 0001h to 0800h
•ASCII: 2,048 bytes (2,048 characters)
•Hexadecimal code: 2,048 bytes (4,096 characters)
End code Indicates the execution result for the command.
The end code 00 indicates normal completion.
For details on end codes, refer to End code List.
p.95
Command
××
aw
××
A/H 1
××
211 4
2
CR
n
××
Command
code
Data
setting
Processing
area
number
setting
Write data
Terminator
Write area
start address
Response
aw
00
22
2
CR
Terminator
Command
code
End code

Related product manuals