About Communication Commands
34
ZFX-C Serial Communication Command Reference
Backing up System Data < SYSSAVE command >
Backing up system data to an external device from the Controller
This command backs up the system data from the Controller by XMODEM protocol.
No parameters are provided for this command.
< Command format >
< File transfer >
The system data is transferred by XMODEM (-CRC or SUM) after READY is received. XMODEM (-1K) is not
supported.
< Response format >
Backing up system data to an SD card from the Controller
This command backs up system data to an SD card from the Controller.
< Command format >
< Response format >
< Explanation of parameters >
File name The file can be given any name within eight alphanumeric characters. (An extension is not
required.)
S Y SS
C
R
SS
C
R
AVE 0 0
OK
C
R
ER
C
R
R EAD
C
R
Y
When processing ends successfully
When processing fails
SYSS
C
R
SS
C
R
AVE11
OK
C
R
ER
C
R
When processing ends successfully
When processing fails