About Communication Commands
38
ZFX-C Serial Communication Command Reference
Restarting the Controller < RESET command >
This command restarts the Controller. No parameters are provided for this command.
< Command format >
< Response format >
Ending Ethernet Communications < EXIT command >
This command ends the TELNET connection for Ethernet communications and disconnects the line.
No parameters are provided for this command.
< Command format >
< Response format >
R E S
C
R
RS
C
R
ET
or
ER
C
R
When processing ends successfully
When processing fails
None
EX
C
R
IT
ER
C
R
When processing ends successfully
When processing fails
None