ONE100 Chapter 2
Installation Guide Directives and Standards
19
2.5 EMC Compliance
•CE
FCC class A
EN55022 Emissions
EN55024 Immunity
EN61000-3-2 Harmonics
EN61000-3-3 Voltage fluctuations and flicker
EN61000-4-2 ESD
EN61000-4-3 Radiated immunity
EN61000-4-4 EFT/burst
EN61000-4-5 Surge
EN61000-4-6 Conducted immunity
EN61000-4-11 Voltage dips & drops
EN300386 EMC Requirements
ETSI EN 301 489-01 Electromagnetic compatibility and radio spectrum matters (ERM); Electromag-
netic compatibility (EMC) standard for radio equipment and services.
ETSI EN 301 489-17 Electromagnetic compatibility and radio spectrum matters (ERM); Electromag-
netic compatibility (EMC) Standard for radio equipment and services; Part 17: Specific conditions for
2,4 GHz wideband transmission systems and 5 GHz high performance RLAN equipment.
EN 62311 Assessment of electronic and electrical equipment related to human exposure restrictions
for electromagnetic fields (0 Hz - 300 GHz).
2.6 Environmental Compliance
Storage conditions: ETSI ETS 300 019-1-1 Class 1.1. In addition, the storage temperature has to be
between -25 and +70°C, with a relative humidity between 0 and 95% non-condensing.
Transport conditions: ETSI ETS 300 019-1-2 Class 2.3.
Stationary use conditions: ETSI ETS 300 019-1-3 Class 3.1. In addition, a relative humidity between
5 and 80% non-condensing and an ambient operational temperature between 0°C and 45°C is sup-
ported.
International protection (IP) class of protection against solid and liquids: IP30