1.
Navigate to Configure > SNMP Alerts > System > System Temperature.
2.
Click on the Alerting button to activate the function, this also activates the
user-defined range sliders.
Note: The Not Alerting button de-activates the function and temperature
alerts will be stopped until activated again.
3.
Click+Drag the temperature range limiters to the required upper and lower lim-
its.
4.
Click Apply. The Details Saved banner confirms your settings.
In this image, if any temperature sensor reports the system temperature (measured
at System Temperature 1 and System Temperature 2 sensors) to be less than 50
degrees C or greater than 99 degrees C, an SNMP alert will be triggered.
Tip: The temperature display is automatically converted to Fahrenheit.