SNMP Alerts Power
Configure > SNMP Alerts > Power > Voltage
The PSU is one of the most critical part of the OM device so it is essential to ensure
that the PSU is operating within its design tolerances.
When voltage SNMP alerts are enabled, network operators are immediately noti-
fied of PSU failures (subject to network connectivity and latency). Should the PSU
begin operating outside design tolerances, PSU-related SNMP Alerts will trigger an
alert for the following conditions:
l
Output DC voltage of both PSUs
If the voltage drops too low, it risks the device going into brown-out state. If it
gets too high, it can damage components.
System generated SNMP Alerts send SNMP traps to a remote SNMP manager
which alerts the user of system events. The OM device can send network, power
and system events to the remote SNMP manager.
Tip: The OM device can send network, power and system events to the remote
SNMP manager.
Configure Power Alerts
Configure > SNMP Alerts > Power > Voltage
The alert related to this functionality is the System Voltage Range alert which
sends an alert when the system reboots or the voltage on either power supply
leaves or enters the user-configured voltage range.