D: 04 Night cooling (Cool at Night) on / off.
In this parameter, the night cooling can be changed.
D: 04 = 0 means cool at night is out. This is the default setting.
D: 04 = 1 means cool at night is on.
If the timer off mode is on, and the minimum temperature is set to e.g. 22 , the unit will
cool the room at 22 in night mode. If the temperature is below 22 the unit will heat up.
In a warm climate, a very well insulated space or other heat sources cannot be deactivated this
function is required to maintain accurate levels.
If the cool at night function is active there will be a moon visible in the display.
D: 05 Heater (Pre-Heat) on / off.
In this parameter, the heating can be turned on.
D: 05 = 0 means pre-heat is off. This is the default setting.
D: 05 = 1 means pre-heat is on.
If pre-heat is activated, the room will heat up for an hour during the day (on timer) the space will
warm up to the set cooling mode (day) temperature. The space is then at the correct temperature
at immediately at the start of each day. Apart from the advantage of the temperature one day
needing a jump-start, this also prevents cold parts which will reduce and prevent mould.
Note: Only works in conjunction with the timer and not in the light cell mode!
D: 06 After heating (slow cool-down) on / off.
In this parameter, the post-heating can be switched on.
D: 06 = 0 means slow cool-down is out. This is the default setting.
D: 06 = 1 means slow cool-down is on.
In slow cool down on, the heating may reduce gradually rather than shut down completely until one
hour after the day has ended to ensure the room cools slowly.
Note: Only works in conjunction with the timer and not in the light cell mode!
D: 07 2 bedrooms 12/12 cooling (dual room) on / off.
In this parameter, the 2 cooling chambers can be turned on.
D: 07 = 0 means dual operation room is off. This is the default setting.
D: 07 = 1 means dual operation room is on. If this function is active, the display shall include the
cottage visible on the screen.
To use this function, there must be a three-way valve and connection ordered to be composed of;
3-way valve, plenum, 2nd temperature sensor and an extensive installation manual / instructions.
D: 08 Alarm output N.Ö. or N.C.
In this parameter, the alarm output can be adjusted.
D: 08 = 0 means N.C. Normally closed. This is the default setting.
D: 08 = 1 means N.Ö. Normally open.
For the correct setting to connect; the user should consult the GSM detector or alarm.