NLV-5201 Specifications Manual
12
8.1.5 RS-232C Interface Cable
RS-232C Interface Cable Specifications
Parameter
Specification
Cable length
1500 mm
Exposed wire length
70 mm
Wire conductor diameter
AWG28
Insulator outer diameter
0.58 mm
Exposed conductor length
7 mm
Cable diameter
φ3.8 mm
Weight
Approx. 45 g
Cable material
PVC
Figure 6: RS-232C Loose End Interface Cable
8.2 USB Interface
The NLV-5201 can use either USB interface:
Human Interface Device Class (HID)
Communication Device Class (COM)
The COM interface allows bidirectional serial communication, which supports transmitting
commands from the host computer to the imager scanner, as well as receiving barcode data. To
use USB-COM, you need to install the latest version of the Opticon USB-COM driver on your
host device.
If the host COM post is not open, the imager scanner cannot send data and will emit an error
sound.
Note: With the USB-COM interface, the imager scanner can transfer images.
1500
±50
60
±5
7
±2
φ3.8
[Unit: mm]