NLV-5201 Specifications Manual
16
Image Range for UD Models
L: Distance from the Front Edge of the
Imager Scanner (mm)
30
40
50
60
80
100
Horizontal Field of View (FOV)
22.7
29.6
36.5
43.4
57.1
70.9
Vertical Field of View (FOV)
17.0
22.1
27.3
32.4
42.7
53.0
Note: The range is ±5% from these values.
10 Technical Specifications
The conditions for technical specifications are as follows, unless otherwise specified in each
section.
Technical Specification Conditions
Specification
Condition
Ambient Temperature and Humidity
Room temperature and room humidity
Ambient Light
100 to 500 lux
Pitch Angle
α = 0°
Skew Angle
β = 15°
Tilt Angle
γ = 0°
Code Position
Near the center of the image
Curvature
R = ∞
Power Supply Voltage
5.0 V
PCS (1D and 2D)
0.9 or higher
Scanning Test
Accept the performance with 90% or more success rate
for 10 scan attempts. One reading should be 2 seconds.
Barcode Test Sample (1D and 2D)
Specified in Barcode Test Labels” on page 17.
Note: For 1D barcodes, use OPTOELECTRONICS test samples. For GS1 DataBar, stacked barcodes, and 2D
barcodes, use barcodes from a dedicated barcode printer.
Figure 11: Test Condition for Depth of Field