8. Technical Specifications
The conditions for technical specifications are as follows unless otherwise specified in each section.
<Conditions>
Temperature and humidity : Room temperature, room humidity
Ambient light : 200 ~ 300 lx
Angles : Pitch: α = 0°, Skew: β = 15°, Tilt: γ = 0°
Curvature : R =
Power supply voltage : 3.7 V
Reading test : 1 read in 0.5 sec or less.
Accept the performance with 10 consecutive successes
Bar code test sample : OPTOELECTRONICS test samples.
Refer to Section 8.1. for details.
8.1. Bar Code Test Sample
<Code 39>
Resolution Symbology PCS
Quiet Zone
()
No. of Digits
1.0 mm 25 mm 1
0.5 mm 18 mm 3
0.25 mm 10 mm 8
0.2 mm 10 mm 34
0.15 mm 7 mm 10
0.127 mm 5 mm 4
0.1 mm
Code 39 0.9
5 mm 4
<JAN>
Resolution Symbology PCS
Quiet Zone
()
No. of Digits
0.26 mm 10 mm 13
0.26 mm 10 mm 8
0.33 mm
JAN 0.9
10 mm 13