b. Verify that the scsi-initiator-id for each host adapter on the second node is set to 7.
Use the show-disks command to nd the paths to the host adapters that are connected to
these enclosures. Select each host adapter's device tree node, and display the node's
properties to conrm that the scsi-initiator-id for each host adapter is set to 7.
{0} ok cd /pci@6,4000/pci@3/scsi@5
{0} ok .properties
scsi-initiator-id 00000007
...
Install the Solaris Operating System, then apply any required Solaris patches.
For the most current list of patches, see
My Oracle Support.
Read the following two conditions carefully to determine whether you must reboot the nodes.
■
If you are using a version of RAID Manager later than 6.22, proceed to Step 7.
■
If you are using a version of the Solaris Operating System earlier than Solaris 8 Update 4,
proceed to
Step 7.
■
If you are using RAID Manager 6.22 and the Solaris 8 Update 4 or later operating
environment, reboot both nodes.
# reboot
Install the RAID Manager software.
For the procedure about how to install the RAID Manager software, see the Sun StorEdge RAID
Manager User’s Guide.
For the required version of the RAID Manager software that Oracle Solaris Cluster software
supports, see
“Restrictions and Requirements” on page 11.
Install patches for the controller modules and RAID Manager software.
For the most current list of patches, see
My Oracle Support.
Check the NVSRAM le revision for the storage arrays. If necessary, install the most recent
revision.
For the NVSRAM le revision number, boot level, and procedure about how to upgrade the
NVSRAM le, see the Sun StorEdge RAID Manager Release Notes.
Check the controller module rmware revision for the storage arrays. If necessary, install the
most recent revision.
For the rmware revision number and boot level, see the Sun StorEdge RAID Manager Release
Notes. For the procedure about how to upgrade the rmware, see the Sun StorEdge RAID
Manager User’s Guide.
5
6
7
8
9
10
Installing Storage Arrays
Chapter 1 • Installing and Maintaining a SCSI RAID Storage Device 15