ESX Issues
The following table lists the ESX VMware issues.
ESX Issues Workaround
“Messages Complain of Failure to Allocate I/O Resources (CR
6984329)” on page 67
Yes
“Option Cards Can Fail to Load Device Drivers in Some Configurations (CR
6933436)” on page 68
Yes
“Warning Messages Appear During Bootup and in Log Files (CRs 6862766,
6861903, and 6890263)” on page 69
N/A
“VMware ESXi 5.5 Does Not Support MMIO Regions Above 4GB (16480679,
17013064)” on page 69
Yes
“VMware ESXi 5.5 Runs Out of Interrupts With PCIe Cards
(16494653)” on page 70
Yes
Messages Complain of Failure to Allocate I/O Resources
(CR 6984329)
Messages that complain about failures to allocate I/O resources might appear in POST, and in
log files.
For example, you might see:
Sep 8 15:50:49 nsg14-28 kernel: PCI: Failed to allocate I/O resource
#2:20@0 for 0000:8d:00.0
Sep 8 15:50:49 nsg14-28 kernel: PCI: Failed to allocate I/O resource
#2:20@0 for 0000:8d:00.1
Workaround
BIOS tries to allocate I/O resources. If it is unable to allocate I/O resources successfully, it
displays error messages.
ESX Issues 67

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oracle Sun Fire X4800 and is the answer not in the manual?

Oracle Sun Fire X4800 Specifications

General IconGeneral
BrandOracle
ModelSun Fire X4800
CategoryServer
LanguageEnglish

Related product manuals