Specications
Sensor:
Operating frequency: 433.92 ± 0.015MHz
Operating voltage: 2.3~3.3V
Operating temperature: -20°C~+80°C/-4°F~+176°F
Pressure range: 0~7.9Bar/0~86PSI
Display:
Operating frequency: 433.92 ± 0.015MHz
Operating voltage: 2.6~3.6V
Operating current: ≤2.5mA
Operating temperature: -20°C~+70°C/-4°F~+158°F
Adjustable Alarm Value:
High pressure value: 2.6~7.9Bar/37~86PSI
Low pressure value: 0.9~3.9Bar/13~55PSI
High temperature value: 70~90°C/ 158°F~ 194°F
Default Value:
High pressure value: 3.3Bar/47PSI
Low pressure value: 1.7Bar/24PSI
High temperature value: 80°C/176°F
Precison:
Temperature: ±3°C/±5°F
Pressure: ±0.1Bar/±0.2PSI
1Bar = 14.5PSI =100K Pa = 1.02kgf/cm
2
NOTE: It is recommended that the tyre pressure alarm values are set to
±25% of the recommended manufacturer tyre pressure values.