Preparation
−11−
Driver
Basic function switch (SW1)
I/O signal connector [CN4]
POWER LED (Green)
ALARM LED (Red)
C-DAT LED (Green)
C-ERR LED (Red)
Internal potentiometer (VR1)
Acceleration/deceleration
time potentiometer (VR2)
Motor signal connector [CN3]
Motor power connector [CN2]
Main po
wer supply input terminal
[CN1]
Electromagnetic brake connector
[CN8]
Communication connector [CN7]
RS-485 communication connector
[CN5/CN6]
ntrol power supply input terminal
(TB1)
Address number setting switch
(SW3)
Communication function switch
(SW2)
Mounting hole (4 places)
Torque limiting
potentiometer (VR3)
Name Description Ref.
POWER LED (Green) This LED is lit while the main power or control power is input. −
ALARM LED (Red)
This LED will blink if an alarm generates (a protective function is
triggered). The alarm type can be checked by counting the number of
times the LED blinks.
P.64
Internal potentiometer (VR1) Sets the motor rotation speed. P.32
Acceleration/deceleration time
potentiometer (VR2)
The acceleration time and deceleration time for starting and stopping
can be set.
P.34
Torque limiting potentiometer (VR3) Sets the torque limiting value of the motor. P.36
Main power supply input terminal [CN1]
Connects the main power supply.
BLV510
,
BLV620
: +24 V
BLV640
: +48 V
P.24
Motor power connector [CN2] Connects the motor power connector.
P.25
Motor signal connector [CN3] Connects the motor signal connector.
Electromagnetic brake connector [CN8]
Connects the electromagnetic brake connector of the motor
(electromagnetic brake type only).
I/O signal connector [CN4]
Uses this connector when using an external control device
(programmable controller) or inputting an operation command.
P.26
Basic function switch (SW1)
Selects the setting of the speed response, external DC voltage and sink
logic/source logic.
P.32, P.35,
P.37
Communication connector [CN7] Connects a PC in which the
MEXE02
has been installed, or the
OPX-2A
. P.29
Control power supply input terminal
*
(TB1) Connects the control power supply of the driver.
Refer to the
USER MANUAL
(RS-485
Communication
Mode).
RS-485 communication connector
*
[CN5/CN6]
Connects the RS-485 communication cable.
C-DAT LED (Green)
*
This LED is lit when the driver communicates with the master station
properly via RS-485 communication.
C-ERR LED (Red)
*
This LED is lit when a RS-485 communication error occurs with the
master station.
Communication function switch
*
(SW2)
Sets the transmission rate, communication protocol and termination
resistor of RS-485 communication.
Address number setting switch
*
(SW3) Sets the address number (slave address) of RS-485 communication.
Mounting hole (4 places) 4 places on the back surface and side surface P.19
∗*
Uses when controlling the system via RS-485 communication.