Setting contents of MEXE02
−54−
11.2 Parameter list
Parameter name Setting range Factory setting Update Ref.
Operation data
Rotation speed
BLV510
: 0, 80 to 3000 [r/min]
BLV620
,
BLV640
: 0, 80 to 4000 [r/min]
0
A
Torque limiting value 0 to 200 [%] 200
Acceleration time 0.2 to 15.0 [s] 0.5
Deceleration time 0.2 to 15.0 [s] 0.5
Function setting
Speed reduction ratio 100 to 9999 100
A
P.56
Speed reduction ratio digit setting ×1, ×0.1, ×0.01 ×0.01
Speed increasing ratio 1 to 5 1
Conveyor speed reduction ratio 100 to 9999 100
Conveyor speed reduction ratio
decimal digit setting
×1, ×0.1, ×0.01 ×0.01
Conveyor speed increasing ratio 1 to 5 1
Rotation speed attainment band 0 to 400 [r/min] 200
Motor rotation direction selection
Positive direction=CCW
Positive direction=CW
Positive direction=CW C
I/O function selection
X0
Not used
FWD (START/STOP)
*
REV (RUN/BRAKE)
*∗
STOP-MODE (FWD/REV)
*
MB-FREE, EXT-ERROR
ALARM-RESET
HMI, M0, M1, M2
FWD (START/STOP)
*
B
P.58
X1 REV (RUN/BRAKE)
*
X2 STOP-MODE (FWD/REV)
*
X3 M0
X4 ALARM-RESET
X5 MB-FREE
Y0
Not used
ALARM-OUT1, WNG, MOVE
TLC, VA, ALARM-OUT2, DIR
ALARM-OUT1
A
Y1 WNG
NET-IN0 input function selection
Not used
FWD (START/STOP)
*
REV (RUN/BRAKE)
*
STOP-MODE (FWD/REV)
*
MB-FREE, HMI, M0, M1, M2
M0
C
NET-IN1 input function selection M1
NET-IN2 input function selection M2
NET-IN3 input function selection FWD (START/STOP)
*
NET-IN4 input function selection REV (RUN/BRAKE)
*
NET-IN5 input function selection STOP-MODE (FWD/REV)
*
NET-IN6 input function selection Not used
NET-IN7 input function selection MB-FREE
NET-IN8 input function selection Not used
NET-IN9 input function selection Not used
NET-IN10 input function selection Not used
NET-IN11 input function selection Not used
NET-IN12 input function selection Not used
NET-IN13 input function selection Not used
NET-IN14 input function selection Not used
NET-IN15 input function selection Not used
*
If the 3-wire mode is selected with the "Operation input mode selection" parameter, the signal in the parentheses ( ) will be applied.