EasyManua.ls Logo

Orved Evox 31 Hi-Line - User Manual

Orved Evox 31 Hi-Line
230 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Evox 31 Hi-Line
VACUUM chamber PACKAGING MACHINES
CONFEZIONATRICI SOTTOVUOTO a campana
CONDITIONNEUSES SOUS VIDE A CLOCHE
ENVASADORAS AL VACÍO de campana
VAKUUMKAMMER-VERPACKUNGSGERÄT
Operating and service manual
Manuale d’uso e manutenzione
Mode d’emploi ed entretien
Manual de uso y mantenimento
Bedienungs- und Wartungsanleitung
E-mail: orved@orved.it - Web site: www.orved.it
Sede legale e amministrativa:
ORVED S.p.A. con SOCIO UNICO
Via dell’Artigianato, 30 - 30024 MUSILE DI PIAVE (VE) ITALY -
Tel.: ++39 0421 54387 / Telefax: ++39 0421 333100
Manual Code 1500339 - Rev. 02 - 06/2018
VACUUM CHAMBER PACKAGING MACHINES
CONFEZIONATRICI SOTTOVUOTO A CAMPANA
CONDITIONNEUSES SOUS VIDE A CLOCHE
ENVASADORAS AL VACÍO DE CAMPANA
VAKUUMKAMMERVERPACKUNGSGERÄT

Table of Contents

Questions and Answers

  • J
    Julie MayerAug 18, 2025
    How to start the pump dehumidification cycle (H2OUT) on Orved Evox 31 Hi-Line Kitchen Appliances?
    • J
      juanpattonAug 18, 2025
      If the display flashes 'RUN H2OUT PRESS START', it means the pump has absorbed moisture. Start the Pump dehumidification cycle (H2OUT) by pressing “START”.
  • M
    Michelle HodgeAug 20, 2025
    What to do if my Orved Evox 31 Hi-Line Kitchen Appliances sealing is not optimal?
    • J
      Joshua SmithAug 21, 2025
      If the sealing isn't optimal, it could be due to several reasons: * The sealing level might not be correct for the bag type. Try adjusting it and repeating the cycle. * Too many consecutive sealing cycles might have been performed, causing overheating. Wait at least 2 minutes between cycles. * The bag might be too large. Use a suitable bag. * The bag edge might not be positioned correctly, or it might be dirty. Position it centrally, protruding about 2 cm, and ensure it's clean. Turn the edge of the bag over so that the outer part remains clean when the product is inserted. Make sure the edge doesn’t form creases near the sealing bar. * The sealing bar and counter-pressure rubber could be dirty or damaged. Clean them. If damaged, contact the Technical Support Service.
  • J
    James WalkerAug 23, 2025
    What to do if Orved Kitchen Appliances displays 'VACUUM NOT STARTED' during a cycle?
    • J
      John GregoryAug 23, 2025
      If the display shows 'VACUUM NOT STARTED' accompanied by an audible signal during a cycle, it indicates that the vacuum isn't activated. This could be because: * The lid hasn't been closed properly. Gently press on the lid to activate the vacuum when the cycle starts. * There is dirt on the lid seal. Clean the vacuum chamber and seal. * The lid seal is broken. Contact the Technical Support Service for replacement. * The pump protection has been activated. Leave the packaging machine to cool. If the fault recurs contact the Technical Support Service.
  • M
    Mr. Matthew Smith MDAug 26, 2025
    What to do if my Orved Evox 31 Hi-Line Kitchen Appliances sealing bar is raised but sealing does not occur?
    • S
      Susan MooreAug 26, 2025
      If the sealing bar is raised but sealing isn't happening, it could be because: * The sealing bar protection device was activated. Restore the sealing bar protection device by pressing the key to restore protection. If the fault recurs contact the Technical Support Service. * The sealing bar is broken. Contact the Technical Support Service.
  • D
    Dylan NolanAug 28, 2025
    What to do if Orved Evox 31 Hi-Line displays 'COOL DOWN PRODUCT OR DECREASE LIQUID PART'?
    • L
      Lisa TurnerAug 28, 2025
      If the display shows 'COOL DOWN PRODUCT OR DECREASE LIQUID PART' accompanied by an audible signal at the end of the cycle, it means the product is either too wet or too hot. If necessary, repeat the cycle by cooling the product or by inserting a lesser quantity of product or liquid.
  • B
    Barry GoldenAug 30, 2025
    What to do if Orved Evox 31 Hi-Line Kitchen Appliances displays 'NO GAS FLUSH' during a cycle?
    • A
      alexanderwallaceAug 31, 2025
      If the display shows 'NO GAS FLUSH' accompanied by an audible signal during a cycle, check the following: * The gas bottle might be empty, closed, or not connected. Change, open, or connect the gas bottle. * The gas bottle connection pipe might be pressed. Replace the connection pipe. * The gas solenoid valve might be faulty. Call an authorized service centre.
  • A
    Amber BakerSep 2, 2025
    What to do if Orved Evox 31 Hi-Line displays 'VACUUM NOT STARTED' during a cycle with external container?
    • J
      Joshua MccarthySep 2, 2025
      If the display shows 'VACUUM NOT STARTED' accompanied by an audible signal during a cycle with an external container, it could be due to: * The lid of the external container is not positioned correctly. Correctly position the lid of the external container. * The external suction device was not properly connected. Correctly connect the external suction device to the packaging machine and to the container.
  • G
    Gregory GonzalezSep 4, 2025
    Why my Orved Evox 31 Hi-Line Kitchen Appliances packaging machine does not switch on?
    • S
      Shawn BurtonSep 5, 2025
      The packaging machine might not be getting power because: * The machine is not powered. Check the power supply to the socket being used. * The power plug is not properly inserted. Insert the power plug into the socket.
  • T
    timothyvalentineSep 7, 2025
    Why is my Orved Kitchen Appliances packaging machine off?
    • J
      Joshua ArcherSep 7, 2025
      The packaging machine might be off due to: * No electrical power. Disconnect the electrical power supply. * An electronic fault. Contact the Technical Support Service.
  • A
    Alexander WilliamsSep 9, 2025
    What to do if too much air remains in the sealed bag with Orved Evox 31 Hi-Line?
    • B
      Breanna LaneSep 9, 2025
      If too much air remains in the sealed bag, consider the following: * The bag may not be the right size for the product. Use a suitably sized bag. * The vacuum level selected may be too low. Repeat the cycle with a higher vacuum level. * If the product is liquid, it is normal for some air bubbles to remain inside.

Summary

Safety Precautions and Warnings

Intended Use

Specifies the correct and intended use of the appliance, excluding improper applications.

Technical Safety

Covers electrical safety, grounding, authorized repairs, and potential hazards from damaged components.

Correct Use

Provides guidelines for proper operation, including temperature hazards, material compatibility, and usage restrictions.

Control Panel

Before Using Evox 31 Hi-Line

Creating a Vacuum in Bags

Creating a Vacuum in Containers

Containers in Vacuum Chamber

Details the procedure for vacuum packaging items using containers placed directly inside the chamber.

External Containers

Explains how to use external containers with the packaging machine via an accessory.

Creating Modified Atmosphere Packaging

Special Functions: Chef Cycles

Cleaning and Maintenance

Pump Oil Dehumidification Cycle (H2 OUT)

Explains the pump oil dehumidification cycle to remove moisture from the vacuum pump.

Pump Oil Dehumidification Cycle (H2 OUT)

Manual Start of the Pump Oil Dehumidification Cycle (H2 OUT)

Provides instructions for manually initiating and completing the pump oil dehumidification cycle.

Troubleshooting

Installation

Safety Instructions

Essential safety guidelines that must be followed during the installation process.

Installation Procedure

Step-by-step procedure for installing the packaging machine in its operating environment.

Maintenance

Technical Data

Warranty

Orved Evox 31 Hi-Line Specifications

General IconGeneral
CategoryKitchen Appliances
ModelEvox 31 Hi-Line
BrandOrved
Sealing bar length310 mm
External dimensions360x510x440 mm
Voltage230 V
Energy Efficiency ClassNot applicable
CapacityNot applicable
Number of Cooking LevelsNot applicable
Power SupplyElectric
Power Consumption0.45 kW
Dimensions (WxDxH)360x510x440 mm
MaterialStainless steel
ColorStainless steel
Control TypeDigital
Temperature RangeNot applicable
TimerYes