EasyManua.ls Logo

Orved MULTIPLE 315VM P8 - User Manual

Default Icon
176 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Manuale d’istruzione
Operating and service manual
Mode d’emploi et d’entretien
Bedienungs- und Wartungshandbuch
Manual de uso y mantenimiento
MULTIPLE 315VM P4-P8 / VM12 / VM16
VM18 / VM18 H / VM53 / VM53 H
VM1800 / VM19 / VM20 / VM30
VM20 TANDEM
CONFEZIONATRICI SOTTOVUOTO A CAMPANA
VACUUM CHAMBER PACKAGING MACHINES
CONDITIONNEUSES SOUS VIDE À CLOCHE
KAMMER - VAKUUM-VERPACKUNGSMASCHINEN
MÁQUINAS ENVASADORAS AL VACÍO DE CAMPANA
REV. 00
Ed. 10 - 2005
Cod.: 1500154
I
GB
F
D
E
ORVED Srl Soc. Unipersonale - Via dell'Artigianato, 30 - 30024 MUSILE DI PIAVE (VE) ITALY
Tel.: ++39 0421 54387 - 340340 / Telefax: ++39 0421 333100 - 332295
E-mail: orved@orved.it - orved.ve@tin.it - Internet: www.orved.it
AZIENDA CON
SISTEMA DI GESTIONE
PER LA QUALITÁ
CERTIFICATO DA DNV
=UNI EN ISO
9001:2000=
COMPANY WITH
QUALITY MANAGE-
MENT SYSTEM
CERTIFIED BY DNV
=UNI EN ISO
9001:2000=

Table of Contents

Questions and Answers

  • T
    Trevor JonesAug 18, 2025
    Why is my Orved MULTIPLE 315VM P8 Kitchen Appliances showing poor sealing?
    • R
      Richard GrayAug 18, 2025
      If your Orved Kitchen Appliances machine isn't sealing properly, start by cleaning the sealing bar. If the issue continues, the sealing time might be insufficient for the bag's thickness. Try increasing the sealing time using the “SEAL” control knob. Also, inspect the Teflon cover and red silicone for wear and replace them if necessary.
  • J
    jessicasandersAug 20, 2025
    What to do if Orved MULTIPLE 315VM P8 Kitchen Appliances does not create vacuum in chamber?
    • L
      Laura ThompsonAug 20, 2025
      If your Orved Kitchen Appliances machine is not creating a vacuum in the chamber, ensure you lower the cover with both hands, applying sufficient pressure during appliance startup. Also, check that the jars evacuation valve (in models MULTIPLE-VM12-VM16) is closed. If you have a model with a gas option, make sure the gas function is deactivated using the “GAS” control knob. Finally, if none of the above work, the pump fuse (PF1) on the power board may have blown; in this case, contact a service center to change the fuse.
  • M
    Melanie BartlettAug 22, 2025
    Why the Orved MULTIPLE 315VM P8 machine does not seal?
    • P
      Patricia ThompsonAug 23, 2025
      If your Orved Kitchen Appliances machine is not sealing bags, first check the sealing bar connection wires and clean the contacts if necessary. If you have a model with a gas option, ensure the gas quantity is not more than 70% by adjusting the “GAS” control knob. Also, verify that the sealing bar fuse (PF2) on the power board is intact and replace it if blown. Finally, make sure the seal bag is not perforated, and replace it if necessary.
  • J
    Jeremy Berry Jr.Aug 26, 2025
    How to fix insufficient vacuum in chamber of Orved MULTIPLE 315VM P8 Kitchen Appliances?
    • S
      Sean ScottAug 26, 2025
      If you're experiencing insufficient vacuum in the chamber of your Orved Kitchen Appliances, first, increase the evacuation time using the “VAC” control knob. Then, check the oil and the pump exhaust filter to ensure the vacuum pump performance is sufficient. If the cover gasket is worn, replace it. For models MULTIPLE - VM12 - VM16, ensure the external containers evacuation valve is closed.
  • S
    Shane MartinezAug 28, 2025
    How to prevent seal seam burns and bubbles in Orved MULTIPLE 315VM P8 Kitchen Appliances?
    • L
      Lindsey RichardsonAug 28, 2025
      If the seal seam of your Orved Kitchen Appliances shows burns and bubbles, it means the sealing time is too long. Decrease the sealing time using the “SEAL” control knob.
  • K
    khamiltonAug 30, 2025
    What to do if Orved MULTIPLE 315VM P8 Kitchen Appliances has insufficient vacuum in bag?
    • W
      William BrownAug 30, 2025
      If you find that the vacuum in the bag is insufficient or the bag does not maintain vacuum with your Orved Kitchen Appliances, ensure the bag is positioned correctly, centered on the sealing bar and projecting 20 mm beyond it. If the bag is perforated, use a thicker bag and wrap the product with cling film or soft paper. If the sealing is insufficient, increase the sealing time using the “SEAL” control knob. Also, check the bag for defects and replace it if necessary. Ensure the bag opening is clean, free from oil or grease, and that the bag size is appropriate for the product dimensions.
  • C
    Christopher MccoySep 1, 2025
    How to troubleshoot Orved MULTIPLE 315VM P8 machine not working?
    • H
      hicksmichaelSep 2, 2025
      If your Orved Kitchen Appliances machine isn't working, first, ensure it's switched on using the main power switch. Next, check the power supply by verifying the plug is correctly inserted into a functioning socket with the correct voltage and that the power cable is intact. Also, inspect fuses PF3 and PF4 on the power board to confirm they are intact and correctly inserted. If the problem persists, it may indicate machine damage, and you should contact a service center.
  • B
    brian89Sep 4, 2025
    Why PLexiglas cover of Orved MULTIPLE 315VM P8 Kitchen Appliances does not close?
    • S
      Stephen ChavezSep 4, 2025
      If the Plexiglas cover of your Orved Kitchen Appliances does not close, the cover gasket may be worn and needs replacement. Alternatively, the hinges might be out of alignment, requiring adjustment; contact a service center for hinge adjustments.
  • J
    Jared BoydSep 6, 2025
    How to fix narrow irregular sealseam on Orved Kitchen Appliances?
    • C
      Chad MaysSep 7, 2025
      If you observe a narrow, irregular seal seam on your Orved Kitchen Appliances, the sealing time is likely too short. Increase the sealing time using the “SEAL” control knob.
  • K
    Kristen PageSep 9, 2025
    What to do if lid opens during GAS cycle of Orved MULTIPLE 315VM P8?
    • R
      Ruth HughesSep 9, 2025
      If the lid of your Orved Kitchen Appliances opens during the GAS cycle, the gas percentage is likely too high. Reduce the gas percentage using the “GAS” control knob.

Summary

Preface

Important Information

Contains critical information for safe and proper use, preservation, and disposal.

General Information

Technical Service and Warranty

Covers warranty terms, duration, conditions, and termination clauses.

General Safety Regulations

Covers general hazards, operator responsibilities, and specific risks during use.

Preliminary Information

Technical Data

Detailed specifications and performance data for various machine models.

Installation

Supply Voltage

Information on connecting the machine to different power supply types.

Control Panel Overview

Explanation of the buttons, displays, and functions on the machine's control panel.

Using the Machine

Digital Control Operation

Instructions for programming and operating machines with digital controls.

Maintenance

Troubleshooting Guide

Identifies common problems and provides solutions for electro-mechanical and digital models.

Orved MULTIPLE 315VM P8 Specifications

General IconGeneral
CategoryKitchen Appliances
ModelMULTIPLE 315VM P8
Sealing bar length315 mm
Pump capacity8 m3/h
TypeVacuum Packing Machine
Voltage230 V
Sealing Time1-9 seconds