OSAKA – USER MANUAL – F 500 / F 500-RS – V.1 – Page 1
11= Reset of HACCP
alarms
12= External "PrA"
alarm
13= External “HP”
alarm
14= External “LP”
alarm
15= Forcing events
Switch on/off (Stand-
by)
16= Start Defrost
17= Stop Defrost
18
i.1t
Delay in acquiring
digital input di1
oF/ 0.01 ÷ 9.59
(min.sec ) ÷
99.5
(min.sec.x10)
oF
19
i.2F
Function and function
logic of digital input
di2: see i.1F
-17 ... 0 ... 17
0
20
i.2t
Delay in acquiring
digital input di2
oF/ 0.01 ÷ 9.59
(min.sec ) ÷
99.5
(min.sec.x10)
oF
21
i.3F
Function and function
logic of digital input
Pr3: see i.1F
-17 ... 0 ... 17
0
22
i.4F
Function and function
logic of digital input
Pr4: see i.1F
-17 ... 0 ... 17
0
23
i.Et
Delay to Eco mode
with door closed
oF = No function
oF/ 0.01 ÷ 9.59
(hrs.min. ) ÷
99.5
(hrs.min.x10)
oF
24
i.tt
Time-out ECO mode.
oF = No function
oF/ 0.01 ÷ 9.59
(hrs.min. ) ÷
99.5
(hrs.min.x10)
oF
25
i.dS
Variable visualized
normally on display:
P1 = meas. probe Pr1
P2 = meas. probe Pr2
P3 = meas. probe Pr3
P4 = meas. probe Pr4
Ec = Pr1 in normal
mode, Eco in Eco
mode
SP= Active Set Point
rE = No function
oF = Display off
P1 / P2 / P3 /
P4 / Ec / SP /
rE / oF
P1
]dF
d. - parameters relative to defrosting control
26
d.dt
Defrosting Type:
EL= Electrical
heating/stop. compr.
in= hot gas/reverse
cycle
no= without compr.
output condictioning
Et= Electrical heating
with evaporator
temperature control
EL / in / no / Et
EL
27
d.dC
Defrosting starting
mode:
rt = real time intervals
ct = “ot” output on time
intervals
cS = defrost every “ot”
switching off (+ rt
intervals)
cL = by real time clock
rt / ct / cS / cL
rt
28
d.di
Defrosting interval
oF/ 0.01 ÷ 9.59
(hrs.min. ) ÷
99.5
(hrs.min.x10)
6.00
29
d.Sd
Delay first defrost after
power-on
(oF = Defrost at power-
on)
oF/ 0.01 ÷ 9.59
(hrs.min. ) ÷
99.5
(hrs.min.x10)
6.00
30
d.dd
Dynamic Defrost
Percentage reduction
0 ÷ 100 %
0
31
d.dE
Lenght (max.) of
defrost cycle (evap. 1)
oF/ 0.01 ÷ 9.59
(min.sec ) ÷
99.5
(min.sec.x10)
20.0
32
d.dL
Defrost display Lock
oF= display free
on= Lock on
temperature Pr1 before
defrost
Lb= Lock on label
“dEF” (during
defrosting) and “PdF”
(during post-defrosting)
oF - on - Lb
oF
33
d.tE
Defrost stop
temperature (evap. 1)
- 99.9 ÷ 999
°C/°F
8.0
34
d.Ei
Defrosting interval for
evaporator probe error
oF/ 0.01 ÷ 9.59
(hrs.min. ) ÷
99.5
(hrs.min.x10)
6.00
35
d.EE
Lengh of defrost cycle
for evaporator probe
error
oF/ 0.01 ÷ 9.59
(min.sec ) ÷
99.5
(min.sec.x10)
10.0
36
d.tS
Defrost enable
temperature
- 99.9 ÷ 999
°C/°F
2.0
37
d.tF
Defrost start
temperature
- 99.9 ÷ 999
°C/°F
-99.9
38
d.St
Defrost start delay for
evaporator
temperature
oF/ 0.01 ÷ 9.59
(min.sec ) ÷
99.5
(min.sec.x10)
1.00
39
d.cd
Delay start Defrost by
continuous compressor
running time
oF/ 0.01 ÷ 9.59
(hrs.min. ) ÷
99.5
(hrs.min.x10)
oF
40
d.td
Compressor delay
after defrost (drainage
time)
oF/ 0.01 ÷ 9.59
(min.sec ) ÷
99.5
(min.sec.x10)
oF
41
d.d2
Lenght (max.) of
defrost cycle
evaporator 2
oF/ 0.01 ÷ 9.59
(min.sec ) ÷
99.5
(min.sec.x10)
oF
42
d.t2
Defrost stop
temperature
evaporator 2
- 99.9 ÷ 999
°C/°F
8.0
]rE
r. - parameters relative to temperature control
43
r.d
Differential
(Hysteresis)
0.0 ÷ 30.0
°C/°F
2.0
44
r.Ed
Differential
(Hysteresis) in Eco
mode
0.0 ÷ 30.0
°C/°F
4.0
45
r.Hd
Differential
(Hysteresis) in Eco
mode in “turbo” mode
or Heating HC mode.
0.0 ÷ 30.0
°C/°F
1.0
46
r.t1
Output activation time
for probe error
oF/ 0.01 ÷ 9.59
(min.sec ) ÷
99.5
(min.sec.x10)
oF
47
r.t2
Output deactivation
time for probe error
oF/ 0.01 ÷ 9.59
(min.sec ) ÷
99.5
(min.sec.x10)
oF