2.2 Specifications
Recommended log length
16 in (406 mm) east-west
Maximum log length
1
18 in (457 mm) east-west
Flue outlet diameter
6 in (150 mm)
Recommended connector pipe diameter
6 in (150 mm)
Type of chimney ULC S635, CAN/ULC-S640, UL 1777
Minimum liner height 12 feet
Baffle material
C-Cast or equivalent
Approved for alcove installation
Not applicable
Approved for mobile home installation
2
No
Type of door
Simple, glass with cast iron frame
Type of glass
Ceramic glass
Blower
Included (up to 144 CFM)
Particulate emission standard
3
EPA / CSA B415.1-10
USA Standard (Safety) UL 1482, UL 737
Canada Standard (Safety) ULC-S628
1
North-south: ends of the logs visible, East-west: sides of the logs visible.
2
Mobile homes (Canada) or manufactured homes (USA): The US Department of Housing and Urban Development describes “manufactured homes”
better known as “mobile homes” as follows; buildings built on xed wheels and those transported on temporary wheels/axles and set on a permanent
foundation. In Canada, a mobile home is a dwelling for which the manufacture and assembly of each component is completed or substantially
completed prior to being moved to a site for installation on a foundation and connection to service facilities and which conforms to the CAN/CSAZ240
MH standard.
3
Tested and certied in compliance with CFR 40 part 60, subpart AAA, section 60.534(a)(1(ii) and ASTM E3053-17. Based on EPA letter dated November
1, 2022.