2. Functionality and connections
2.1 Controls
If one of these controls is activated, and the safety contacts are not operated, the chairlift will start to
move in the controlled direction.
Control input connected to connector-name
Control armrest right (NO) X2a-
1,3 Arm1
Control armrest left (NO) X2a-
2,3 Arm1
2-channel receiver (Remote right) (NO) X8-
3,4 Remote
2-channel receiver (Remote up) (NO) X8-
5,6 Remote
2.2 Safety inputs
If one of these safety devices is controlled the lift can not be moved in any direction.
Control input connected to connector-name
Armrest-switch (NC) X2b-
1,2 Arm 2
Swivelseat switch (NC) X2c-
1,2 Seat
1-channel receiver/hinge PCBssp 008/sensor(NC) X7-3,4 & 5,6 Extra Contact
Overspeed governor (catch) (NC) X9b-
1,2 Catch
2.3 Sensitive edges safety inputs
Sensitive edges safety inputs right side
If one of these safety devices are controlled, the lift can not move in the right direction.
It is still possible for the lift to move in the left direction.
Control input connected to connector-name
Endswitch right (NC) X3a-
1,2 Endswitch
Safety drive unit right (NC) X4-
1,2 Drive
Safety footrest right (NC) X5-
1,2 Foot
Safety chairframe right (NC) X6-
1,2 Frame