46
TROUBLE SHOOTING
Symptom Problem Solution
Lid “tops out” cylinder on the Lid is missing micro switch arm. Adjust arm – side to side, up and
up stroke and the crusher down or rotate arm. (See page 32.)
continues to build pressure.
(Diesel engine will stay on Lid hits switch but does not stop. Check arm operation & electrical
high idle.) connection. (See page 18.)
Lid stops approximately 2 feet Micro switch arm hits the top Adjust load if the lid is coming off
from the top. of the lid instead of the stop tab. off an uneven bundle.
Adjust arm – side to side up and
down or rotate arm. (See page 32.)
Lid stops ¼ - ½ of the way up. Micro switch arm stuck in up Check arm alignment and it’s
position. movement up and down. (See page 32.)
Bad electrical connection. Check wiring inside of micro switch.
Disconnect two-pin connector to micro
switch to see if remote will lift lid with
automation system. (See page 18.)
Lid will not release to go back Automation system not receiving Check two pin electrical connection to
up on automated cycle. signal from pressure switch. pressure switch. (See page 18.)
Check connection to automation box
by jumping connection to white
automation box with wire or paper clip.
(The automation light should come on.)
Pressure switch setting too high. Decrease pressure by turning switch
adjustment counterclockwise. (See
page 10.)
Switch is plugged or stuck. Check and clean pressure switch and
snubber filter while tapping them to
loosen debris.
Light on the white automation Pressure switch setting too low. Increase pressure by turning switch
control box stays on all the time. adjustment clockwise. (See page10.)
Switch is plugged or stuck. Check and clean pressure switch and
snubber filter while tapping them to
loosen debris.
Wire harness or receiver is faulty. Swap the two pin electrical connections
going to the left and right switches. If
the same light remains on replace
receiver. (See page 18.)