Code list TC166
13
Subject to change without notice
53
Code
nr.
Password
protected
Set
value
Unit Title Description
135
136 no Set-up time
137 yes 0
1
not active
active
Cycle time reduction - Welding heads starts as the same time as elevation table "up".
140 Display for actual sheet length
141 Display for the result of the measurement of the last bad sheets.
142 m/min Display for the speed of the transport belts
143 date Last software change
144 yes 1/1000 sec Delay 12 Welding time monitoring - if the heating dies are heated for a long time, the machine is
stopped with Error 18
145 no Display for cycles until machine stops with Error 42 running out of banding.
150 yes 0
1
not active
active
By activating Total Reset, all memory will be deleted. All variable values will be deleted. All
code values will return to basic setup
170 no 0
1
Operating mode paper banding
Operating mode plastic PE-banding
171 no 40 1/100 sec Delay 13 Heating time for PE-banding
172 no 3 1/100 sec Delay 14 Cutting time for PE-banding
173 no 100 1/100 sec Delay 15 Cooling time for PE-banding
175 yes 1 Delay 17 Starting delay for small-package facility
176 yes 1 Delay 18 Switch-off delay for small-package facility
203 no Input display - Inputs can be checked during operation using cursor up / cursor down keys
204 no Output display - Outputs can be checked during operation using cursor up / cursor down