Code list TC161
14
Subject to change without notice
57
Code-
Nr.
Password
protected
Set
value
Limit
-
Limit
+
Unit Title Description
170 yes 0
1
Operating mode paper banding
Operating mode plastic PE-banding
171 no 400 300 800 ms. Delay 13 Heating time for PE-banding
172 no 300 200 3000 ms Delay 14 Cutting time for PE-banding
173 no 1000 300 10000 ms Delay 15 Cooling time for PE-banding
175 yes 10 0 5000 ms Delay 17 Starting delay for small-package facility
176 yes 10 0 5000 ms Delay 18 Switch-off delay for small-package facility
177 yes 2500 0 5000 ms Waiting time valve
manually
left
178 yes 2500 0 5000 ms Waiting time valve
manually
right
181 yes 0 2000 ms Delay external stop
signal
182 yes 2500 0 5000 ms Waiting time valve Side loader left
183 yes 2500 0 5000 ms Waiting time valve Side loader right
185 yes 50 0 ms Delay19 Reaction time of the deflector valve
186 yes 50 0 ms Duration How long the deflector valve is activated.
196 BA700 Display BA type BA700, BA900, BA700-A
197 yes Automatic sheet counter Simulates the sheet counter. The product infeed can be simulated.
203 no Input display - Inputs can be checked during operation using cursor
up / cursor down keys
204 no Output display - Outputs can be checked during operation using
cursor up / cursor down keys