19 1-2017
Translation
3.9 Emergency stopping of an electrically powered machine, Fig. 8
Push down the emergency stop button D.
Turn the pushbutton clockwise to release it.
3.10 The machine is equipped with a system to prevent simultaneous op-
eration in two modes, Fig. 9
When the cover plate B is turned down, it is possible to connect the extension cord.
When the cover is raised up, it is possible to connect the PTO shaft.
Suspension hook A for the PTO shaft.
Fig. 9
WARNING! Never remove from the machine the plate that prevents the simultane-
ous operation in two modes.
Always remove the PTO shaft before operating the machine by electricity.
3.11 Operation under cold conditions
When an electrically powered machine is operated in a temperature below -10 degrees
Centigrade, we recommend using less viscous hydraulic oil, such as ISO VG22S multi-
grade oil or synthetic hydraulic fluid, because a machine with electric drive takes full revo-
lutions right from the start of operation.
In cold weather, it pays to reduce the speed of the discharge conveyor to a minimum. Do-
ing it this way requires the least power at the start-up stage.
It also pays to pull down the disengagement lever for the transmission for a cold start.
Then only the angular gear will start running and the gearbox oil will warm up. After this,
stop the machine, release the disengagement lever for the transmission and restart the
machine.