Chapter 4 Overview
23
Overview of the function assignment
Linear levers 5, 6, 7 and 8 are assigned depending on the
equipment of the crane.
Linear lever 8 can be switched and can be used for 2
ancillary devices.
60 70 9080 100
1
2
3
4 5
6
7
8
Linear levers 5 and 6 are assigned depending on the
equipment of the crane.
60 70 9080 100
1
2
3
4
5
6
Emergency cut-off button
The emergency cut-off button stops all crane functions within 0.5 seconds (500 ms) after activation in
an emergency situation.
An emergency cut-off button can be found at every operating station and on the remote control
handset.
1. In dangerous situations let go all operating levers immediately.
2. Press the emergency cut-off button until it locks.
All crane functions stop.
Danger! Releasing the emergency cut-off button before ensuring
safe crane operation leads to acute risk of fatal injury.
Release the emergency cut-off button only in safe working conditions.