Type | Ultrasonic Flow Meter |
---|---|
Accuracy | ±0.5% of reading |
Repeatability | ±0.2% of reading |
Operating Temperature | -40°C to 60°C (-40°F to 140°F) |
Measurement Principle | Transit time |
Technology | Ultrasonic |
Flow Tube Types | Clamp-on |
Temperature Range | -40°C to 60°C (-40°F to 140°F) |
Power Supply | 100 to 240 VAC, 50/60 Hz |
Outputs | 4-20 mA, Pulse, Alarm |
Communication Protocols | HART, Modbus |
Enclosure | IP66 |
Display | Backlit LCD |
Provides an overview of programming the GF868 flowmeter and its key features.
Explains the function and use of the GF868's 39-key keypad for programming.
Details the procedure for entering channel-specific data like activation, system, and pipe parameters.
Covers programming non-channel-specific parameters such as clock, system units, I/O, and communications.
Describes how to store and retrieve programmed meter configurations as site files.
Explains how to display measurement data in various formats using the GF868's display menu.
Details BIG, DUAL, and GRAPH display formats for viewing single or multiple measurements and trends.
Covers displaying logged data numerically or graphically and visualizing transducer signals.
Explains how to adjust LCD backlight settings and activate the sleep mode for power saving.
Introduces the GF868's data logging capabilities via the LOG menu and its submenus.
Guides users through creating standard logs, selecting parameters, and setting log timing.
Details how to check memory status and terminate active logging processes.
Explains how to create specific logs that record error conditions and associated data.
Describes how to print data from the GF868's memory via the RS232 port using the PRINT menu.
Covers printing live and logged data in both numeric and graphical formats.
Explains how to print site files and stop active printing jobs.
Details printer setup and printing specific data like signal arrays and RTD values.
Explains how to purge the GF868's memory of measurement totals and files using the CLEAR menu.
Guides on resetting volumetric totals and the stopwatch totalizer.
Details the process for removing site parameter files and log files from memory.
Introduces serial interface capabilities for uploading log files and communicating with PCs.
Covers wiring the RS232 interface, checking baud rate, and terminal software setup.
Describes the optional RS485 serial interface, including wiring and configuration.
Explains how to set up Ethernet and MODBUS/TCP connections for network communication.
Provides a table to record installed option card types and their setup information.
Details initial setup data entry required after flowmeter installation.
Introduces the PanaView graphical interface for PC-based instrument communication.
Guides on setting up communication ports for PanaView, including Ethernet and RS232.
Explains how to add the GF868 meter to the PanaView software's network tree.
Covers editing meter clock, signals, totalizers, and handling site files via PanaView.
Lists available measurements provided by Foundation Fieldbus analog input blocks.
Guides on using configuration utilities to select measurements for AI blocks.
Explains selecting units for AI blocks and resetting instrument totalizers.
Provides an example setup using function blocks for application configuration.