Item Setting details
CAM1 to CAM99 IP
ADDRESS
Sets the IP address of the camera.
The setting ranges are as follows.
(IP addresses are assigned in order starting with 192.168.0.20 for CAM1 under factory default con-
ditions.)
1st octet: 1 to 223
2nd octet: 0 to 255
3rd octet: 0 to 255
4th octet: 1 to 254
However, the following addresses cannot be set.
Check the setting values during configuration.
0.*.*.*, *.*.*.0, *.*.*.255, 127.0.0.1
Class D address (224.0.0.0 to 239.255.255.255)
Class E address (240.0.0.0 to 255.255.255.255)
CAM1 to CAM99 PORT Sets the port of the camera.
Values from 1 to 65535 can be set.
(Factory default: 49152)
CAM1 to CAM99 INF
UPLOAD
When you press the [MENU] dial, the camera's IP address and port will be set.
Performing [UPLOAD] after changing the settings will apply the setting value changes. Perform [UPLOAD] on each screen. The
settings will not be applied unless [UPLOAD] is performed.
- 119 -