1. Input an NTSC full field color bar signal.
2. Set the monitor to the FACTORY mode, then select PICTURE REF from the menu, and then
adjust CHROMA and PHASE on the PICTURE REF menu to align the vertical positions of A,
B, C, and D of the pulse below by using the doted lines as a guideline.At this time, adjust
CHROMA for A and D and PHASE for B and C.
3. Input a PAL full field color bar signal.
4. Check that the variations of the vertical positions of A, B, C, and D are within 5 V.
•@