13 SAFETY DEVICE
INDOOR UNIT
Indoor unit Model CS-A18BD3P
For fan motor protection
Internal OFF °C 135
protector (49F) ON °C 85
For control protection Fuse CUT A 3.15
OUTDOOR UNIT
Outdoor Unit Heat pump model 50Hz CU-A18BBP5
Cooling only 50Hz CU-C18BBP5
model
For Refrigerant Cycle, OFF MPa -
High Pressure Switch (63H
1
) ON MPa -
For
Compressor
Over Current
Protection
OFF A 15.5
(Heat pump)
OFF A 15.5
(Cooling 50Hz
only) A -
60Hz
RESET - Automatic
Discharge Temp. Compressor °C -
Protection, OFF
Discharge Temp.
Thermistor (Th1)
Liquid Compression Protection, Crankcase
Heater
Input power W -
Compressor Protection, OFF °C 50Hz 150
Internal Protector ON °C 50Hz 90
Trip time 50Hz 3-10sec/44A
For Fan Motor Protection, OFF °C 50Hz 135
Internal Protector (49F) ON °C 50Hz 85
Heating Pressure switch (Heat OFF MPa 2.35
pump only) (Fan speed) (63H
2
) ON MPa 2.25
Cooling Control,
Heat Exchanger
Outlet Temp. Thermistor (Th2)
Control
method
-
For Control Protection, Fuse CUT A 6.3
(*) 1MPa = 10.2kgf/cm
2
(*) Head Thermostat
30