13.2. Sensible Capacity Chart
CS-E15DB4EW CU-E15DBE
Outdoor Temp. (°C)
Indoor wet
bulb temp.
30 35 40 46
TC SHC IP TC SHC IP TC SHC IP TC SHC IP
17.0°C 4.07 3.08 1.19 3.80 2.96 1.28 3.53 2.84 1.37 3.21 2.70 1.48
19.0°C 4.10 1.30
19.5°C 4.46 3.23 1.21 4.17 3.10 1.31 3.88 2.99 1.40 3.53 2.84 1.51
22.0°C 4.87 3.35 1.24 4.55 3.22 1.33 4.23 3.11 1.42 3.85 2.96 1.53
CS-E18DB4EW CU-E18DBE
Outdoor Temp. (°C)
Indoor wet
bulb temp.
30 35 40 46
TC SHC IP TC SHC IP TC SHC IP TC SHC IP
17.0°C 4.76 3.61 1.40 4.45 3.46 1.51 4.14 3.33 1.61 3.76 3.16 1.74
19.0°C 4.80 1.53
19.5°C 5.23 3.78 1.43 4.89 3.63 1.54 4.55 3.50 1.64 4.13 3.33 1.77
22.0°C 5.70 3.92 1.45 5.32 3.77 1.56 4.95 3.64 1.67 4.50 3.47 1.80
CS-E21DB4ES CU-E21DBE
Outdoor Temp. (°C)
Indoor wet
bulb temp.
30 35 40 46
TC SHC IP TC SHC IP TC SHC IP TC SHC IP
17.0°C 5.85 4.44 1.88 5.47 4.26 2.02 5.09 4.09 2.16 4.63 3.89 2.33
19.0°C 5.90 2.05
19.5°C 6.43 4.65 1.91 6.01 4.46 2.06 5.59 4.30 2.20 5.08 4.09 2.37
22.0°C 7.00 4.82 1.95 6.54 4.63 2.10 6.09 4.47 2.24 5.53 4.26 2.42
TC - Total Cooling Capacity (kW) Indoor 27°C/19°C
SHC - Sensible Heat Capacity (kW) Outdoor 35°C/24°C