6
2. Specifications
Indoor CS-E7PKEW, CS-XE7PKEW CS-E9PKEW, CS-XE9PKEW
Model
Outdoor CU-E7PKE CU-E9PKE
Performance Test Condition EUROVENT EUROVENT
Phase, Hz Single, 50 Single, 50
Power Supply
V 230 230
Min. Mid. Max. Min. Mid. Max.
kW 0.75 2.05 2.40 0.85 2.50 3.00
BTU/h 2560 6990 8180 2900 8530 10200
Capacity
Kcal/h 650 1760 2060 730 2150 2580
Running Current A – 2.15 – – 2.40 –
Input Power W 240 465 570 245 530 720
Annual Consumption kWh – 233 – – 265 –
W/W 3.13 4.41 4.21 3.47 4.72 4.17
BTU/hW 10.67 15.03 14.35 11.84 16.09 14.17
EER
Kcal/hW 2.71 3.78 3.61 2.98 4.06 3.58
Pdesign kW 2.1 2.5
SEER (W/W) 6.7 6.6
Annual
Consumption
kWh 110 133
ErP
Class A++ A++
Power Factor % – 94 – – 96 –
dB-A 37 / 24 / 20 39 / 25 / 20
Indoor Noise (H / L / QLo)
Power Level dB 53 / – 55 / –
dB-A 45 / – 46 / –
Cooling
Outdoor Noise (H / L)
Power Level dB 60 / – 61 / –
kW 0.75 2.80 4.00 0.85 3.40 5.00
BTU/h 2560 9550 13600 2900 11600 17100
Capacity
Kcal/h 650 2410 3440 730 2920 4300
Running Current A – 2.85 – – 3.35 –
Input Power W 230 630 1.01k 240 730 1.29k
W/W 3.26 4.44 3.96 3.54 4.66 3.88
BTU/hW 11.13 15.16 13.47 12.08 15.89 13.26
COP
Kcal/hW 2.83 3.83 3.41 3.04 4.00 3.33
Pdesign kW 2.1 2.7
Tbivalent °C -10 -10
SCOP (W/W) 4.3 4.1
Annual
Consumption
kWh 684 922
ErP
Class A+ A+
Power Factor % – 96 – – 95 –
dB-A 38 / 25 / 20 40 / 27 / 20
Indoor Noise (H / L / QLo)
Power Level dB 54 / – 56 / –
dB-A 46 / – 47 / –
Heating
Outdoor Noise (H / L)
Power Level dB 61 / – 62 / –
Low Temp. : Capacity (kW) / I.Power (W) / COP 2.90 / 890 / 3.26 3.62 / 1.14k / 3.18
Extr Low Temp. : Capacity (kW) / I.Power (W) / COP 2.35 / 910 / 2.58 2.88 / 1.16k / 2.48
Max Current (A) / Max Input Power (W) 4.5 / 1.01k 5.7 / 1.29k
Starting Current (A) 2.9 3.35