13.13 Mild Dry Cooling Operation
This operation helps to prevent decreases in room humidity while maintaining the setting temperature.
During unit running at Cooling operation mode, if “Mild Dry Cooling” button is pressed, Mild Dry Cooling operation
starts and Mild Dry Cooling indicators turns ON at remote control display.
Mild dry cooling operation is unavailable when the unit is operating Auto mode and Soft Dry model operation.
Mild dry cooling operation is cancelled when the unit turned OFF, Mild Dry Cooling button is pressed again or
when the operation mode changed from Cooling to other mode.
ECONAVI, Powerful, Quiet and Mild Dry Cooling mode cannot function at the same time, the unit will follows the
operation according to the last signal received.
During this operation, the compressor frequency changes according to operating condition to prevent room
humidity decreases and when AUTO AIR SWING is set, the vertical airflow direction fixed at lower limit position.
13.14 AUTO COMFORT and ECONAVI Operation
Area of human availability, activity level and absent is judged based on pulses by using 2 infrared sensors. The
internal setting temperature shift, fan speed and horizontal airflow direction are adjusted in order to provide
comfort environment while maintain the energy saving level.
AUTO COMFORT start condition:
o When AUTO COMFORT button is pressed.
AUTO COMFORT stop conditions:
o When AUTO COMFORT button is pressed again.
o When unit is OFF by OFF/ON button.
o When unit is OFF when OFF TIMER activates.
o When unit is OFF by AUTO OFF/ON button at indoor unit.
o When POWERFUL, QUIET operation activates.
o When ◄► button is pressed.
ECONAVI start condition:
o When ECONAVI button is pressed.
ECONAVI stop conditions:
o When ECONAVI button is pressed again.
o When unit is OFF by OFF/ON button.
o When unit is OFF when OFF TIMER activates.
o When unit is OFF by AUTO OFF/ON button at indoor unit.
o When POWERFUL, QUIET operation activates.
o When ◄► button is pressed.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-E7PKEW and is the answer not in the manual?

Panasonic CS-E7PKEW Specifications

General IconGeneral
Indoor unit typeWall-mountable
Indoor unit weight10000 g
Indoor units quantity1
Cooling airflow (indoor unit)732 m³/h
Heating airflow (indoor unit)768 m³/h
Indoor unit dimensions (WxDxH)870 x 255 x 295 mm
Indoor unit noise level (high speed)38 dB
TypeAir conditioner indoor unit
Ionizer-
Remotely operatedYes
Cooling capacity (max)7000 BTU/h
Air conditioner functionsCooling, Heating
Cooling capacity in watts (max)2400 W
Cooling capacity in watts (min)750 W
Heating capacity in watts (max)2800 W
Cooling energy efficiency (EER, W/W)4.41
Heating energy efficiency (COP, W/W)4.44
Seasonal efficiency rating (cooling) (SEER)6.7
Seasonal efficiency rating (heating) (SCOP) (Average heating season)4.3
Noise level (low speed)20 dB
Noise level (medium speed)25 dB
Power requirements230V, 10A
Power consumption (cooling) (max)- W
Power consumption (heating) (max)1010 W
Power consumption (heating) (min)230 W
Annual energy consumption (cooling)110 kWh
Annual energy consumption (heating) (Average heating season)684 kWh

Related product manuals