51
18°C
11°C
Max 70Hz Min 16Hz
Free
Outdoor air
temperature
17°C
10°C
Max 99Hz Min 16Hz
13.3.3.2 Intake Air Temperature Control
Compressor operating frequency changes in accordance to the outdoor air temperature.
This control is not applicable during minimum frequency operation protection control, deice operation, pump
down operation.