EasyManua.ls Logo

Panasonic CS-PV9DKE

Panasonic CS-PV9DKE
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18
8.3.Automatic Mode Operation
Standard for Determining Operation Mode
Cooling mode
Soft Dry mode
Cooling mode
Soft Dry mode
IntakeAir
temperature
Setting Temperature (Standard)
23
25
22
One hour after the above determination, the unitwill operate accordi ng to the tablebelow.
First
determination
Cooling
Dry
Second Determination
Cooling
Dry
23 or above
20 or above
Second Determination:
First Determination:
Higher
Standard
Lower
2
0
2
Indoor fan operates at super low speed for 25 seconds.
After judging indoor air temperature, the operation is determined and operation continued at the mode determined.
After the operation mode has been determined, the mode does not change.However, Soft Dry mode operation
includes cooling mode operation.
If automatic mode operation is started while the unit is operating, operation will continue.
If current operation is in cooling mode (including the cooling mode operation when is a part of Soft Dry mode
operation)
itwill be maintained, and if current operation is not cooling mode, the appropriate operation mode is
determined for 25seconds at super slow fan speed. Then the selected mode will continue.
Room temperature adjustment
A)
B)
C)
D)
E)
F)
8.4.AirCirculationMode Operation
1. An additional heater may make the warm air evenly covering each corner of the room.
2. When the temperature near the ceiling reaches the setting temperature, AirCirculation Mode Operation commences
at low airflow volume.It stops when the temperature drops to 2 below the setting temperature.
3. The vertical airflow direction louver will not swing.
CS-PV9DKE / CU-PV9DKE / CS-PV12DKE / CU-PV12DKE

Related product manuals