8.11.Airflow Direction Control
Airflow Direction Auto-control
The left and right airflow direction louver can be adjusted manually.
When set at airfl ow direction auto-control with remote control,the louver swi ngs up and down as shown in the tablebelow.
The louver does not swing when the indoor fan stops during operation.
When stop the unitwith remote control,the discharge vent isclosed with the louver.
Cooling
Soft dry
Operating Mode
Determining operation
mode
Manual
Auto
12 34 5
12 17 26 32 36
oo o o o
12 ~36
oo
9
o
Airflow direction manual control
Angles OfAirflow Direction Louver
Notes:
In cooling or soft dry mode operation
If the compressor continues to operate for 60 minutes ,and the louver direction isatNo 5,the fan speed isbelow Med, the intake
air temperature isbelow 29 and continues to change between 2 for 30 minutes ,the louver direction will be at No 2in order
to prevent dew around the discharge vent.
When the airflow direction set button is pressed,the automaticairflow isreleased and the airflow direction louver
moves up and down as shown in thetablebelow. The louver can be stopped by releasing the button at the desired
position.
When the remote controlis used to stop the operation,the discharge vent isclosed with airflow direction louver.