Air Quality Control
Detecting ofair quality(Whenthe air conditioner is on standby.)
Rs/MAXR will be calculated automatically every2secondsand the air quality level will bedetermined in
accordance with the value below,
Signal of Air Quality Sensor
Air Quality Level
A i r Quality
Getting Worse
A i r Quality
Getting Better
Rs/MAXR G1
(0)(1)
Rs/MAXR G2
(2)(1)
Rs/MAXR G3
(2) (1)
Rs/MAXR G4
(1) (0)
Air Quality Level and Indicator
During preheating ofthe air quality sensor the air quality indicator is red.
The color ofthe air quality indicator varies with the air quality level:
Air PollutionLevel 0: Green
Air PollutionLevel1:Orange
Air PollutionLevel 2:Red
(0)
(1)
(2)
*G1=0.85
*G2=0.60
Setthe sensitivity number ofthe air quality sensor as 2 (Standard)
A i r q uality
becomes better
A i r q uality
becomes worse
Detecting ofair quality( Whenthe air conditioner is on standby.)
(a) After the air conditioner stops operation, it will providespower to the air quality sensor intermittently todetect
the air quality and update theresistancereference (MAXR). The p
ower ofthe air quality sensor will beonfor 3
minutes after each 109 minutes.
During these3minutes, the air quality sensor will be in preheating process for 2 minutesand theother time is
for measuring theresistance.The air conditioner will compare the maximum resistance measured in this per
iod
with the maximum value in the previous 109 minutesand the bigger one will be selected as resistance