7
Indoor CS-RE18QKE CS-RE24QKE
Model
Outdoor CU-RE18QKE CU-RE24QKE
Fin Material Aluminium (Pre Coat) Aluminium (Pre Coat)
Fin Type Slit Fin Slit Fin
Row × Stage × FPI 2 × 15 × 17 2 × 15 × 21
Indoor Heat
Exchanger
Size (W × H × L) mm 810 × 315 × 25.4 810 × 315 × 25.4
Fin Material Aluminium (Pre Coat) Aluminium (Pre Coat)
Fin Type Corrugated Fin Corrugated Fin
Row × Stage × FPI 2 × 31 × 19 2 × 30 × 19
Outdoor
Heat
Exchanger
Size (W × H × L) mm 36.4 × 651 × 854.5:824.5 38.1 × 762 × 895.8:865.8
Material Polypropelene Polypropelene
Air Filter
Type One-touch One-touch
Power Supply Indoor Indoor
Power Supply Cord A Nil Nil
Thermostat Nil Nil
Protection Device Electronic Contol Electronic Contol
Dry Bulb Wet Bulb Dry Bulb Wet Bulb
Maximum °C 32 23 32 23
Cooling
Minimum °C 16 11 16 11
Maximum °C 30 – 30 –
Indoor
Operation
Range
Heating
Minimum °C 16 – 16 –
Maximum °C 43 26 43 26
Cooling
Minimum °C -10 – -10 –
Maximum °C 24 18 24 18
Outdoor
Operation
Range
Heating
Minimum °C -15 -16 -15 -16
1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb
(44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
3. Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature of 20°C, outdoor 2/1°C.
4. Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature of 20°C, outdoor -7/-8°C.
5. Standby power consumption ≤2.0w (when switched OFF by remote control, except under self protection control).
6. Specifications are subjected to change without prior notice for further improvement.