87
17. Technical Data
Technical data provided are based on the air conditioner running under free frequency.
17.1 Cool Mode Performance Data
Unit setting: Standard piping length, Hi Fan, Cool mode at 16°C
Voltage: 230V
CS-RE18QKE/CU-RE18QKE
Indoor (°C) Outdoor DB (°C)
-10 -7 0 5 16 25 35
DB WB
TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP
19.0 5707 4196 1028 5959 4294 938 5528 4143 1106 5716 4200 1019 5620 4200 1013 5229 3971 1273 5000 4040 1470
27
22.0 6546 3429 898 6270 3275 1014 6053 3254 1155 5853 3163 1071 6062 3341 1016 5686 3142 1287 5242 2398 1489
15.7 5022 4003 1134 5066 4062 1135 5179 4033 1047 5119 4023 1079 5211 4044 1013 4838 3886 1249 4347 3698 1552
23
18.4 5614 3228 1038 5379 3147 1143 6068 3376 911 5532 3063 1126 5688 3192 1015 5318 3024 1262 4785 2847 1580
13.3 4421 3794 1125 4205 3671 1242 4260 3685 829 4258 3704 921 4556 3849 848 4531 3844 1248 4008 3557 1525
20
15.8 4409 2845 1299 4679 2943 1176 4482 2853 862 5023 3158 791 6087 3551 1374 5430 3291 1602 4477 1581 1661
(Dry bulb value based on 46% humidity)
CS-RE24QKE/CU-RE21QKE
Indoor (°C) Outdoor DB (°C)
-10 -7 0 5 16 25 35
DB WB
TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP
19.0 7761 5367 1468 8105 5493 1340 7519 5299 1580 7774 5373 1455 7644 5373 1447 7112 5079 1818 6800 5168 2100
27
22.0 8903 4387 1283 8528 4190 1448 8232 4163 1649 7961 4047 1529 8244 4274 1451 7733 4020 1838 7129 3067 2128
15.7 6830 5121 1620 6889 5196 1622 7043 5160 1495 6961 5146 1541 7088 5173 1447 6580 4970 1784 5912 4731 2217
23
18.4 7636 4129 1483 7316 4026 1633 8252 4319 1301 7523 3918 1609 7736 4083 1450 7233 3869 1803 6508 3642 2258
13.3 6012 4853 1607 5719 4696 1774 5794 4714 1184 5790 4738 1315 6196 4923 1211 6163 4918 1783 5451 4550 2179
20
15.8 5997 3640 1855 6364 3765 1680 6096 3650 1231 6831 4040 1129 8279 4542 1962 7385 4209 2288 6089 2023 2373
(Dry bulb value based on 46% humidity)