11.9 Indication Panel
LED POWER TIMER QUIET POWERFUL e-ion Mild Dry PATROL
Color Green Orange Orange Orange Blue Blue Blue Orange Red
Light ON Operation ON Timer Setting ON Quiet Mode ON Powerful Mode ON e-ion ON Mild dry ON Air Clean Moderate Dirty
Light OFF Operation OFF Timer Setting OFF Quiet Mode OFF Powerful Mode OFF e-ion OFF Mild dry OFF PATROL OFF
Note:
• If POWER LED blinks, the possible operation of the unit is operation mode judgment, or ON timer sampling.
• If TIMER LED blinks, there is an abnormal operation occurs.
• If e-ion LED blinks, there is an abnormal e-ion operation occurs.
• If PATROL LED blinks, there is gas sensor error detection.
11.10 Patrol Operation
• To monitor air dirtiness level by using Patrol sensor and to maintain air freshness by activates e-ion operation
• Patrol operation starts condition
o When the unit operation is started with “OFF/ON” button
o When the unit stops, “Patrol” button is pressed, Patrol individual operation will start.
o During cooling only operation, “Patrol” button is pressed.
• Patrol operation stops condition (when any of the following condition is fulfilled):
o When “OFF/ON” button is pressed.
o During any operation with Patrol, “Patrol” button is pressed again.
o When “e-ion” button is pressed.
o When OFF Timer activates.
• Patrol operation disable
o To disable the Patrol Operation during unit starts (default) with “OFF/ON” button, press “Patrol” button and
hold for 5 seconds, then release.
o To disable the Patrol Operation, press “Patrol” button and hold for 15 seconds, then release.
e-ion activates when
Patrol LED turns red.